Anton Paar AFM
Location | 140 Engineering Tower |
Contact: | Dr. Jian-Guo Zheng |
Email: | jzheng@uci.edu |
EMERGENCY: | 9-1-1 |
UCI Police: | (949) 824-5223 |
UCI Medical Center: | (714) 456-6123 |
Usage ($) | Training ($) | |
UC Campuses |
20 | 40.00 |
Other Academic |
26 | 52.00 |
Industrial |
60 | 120.00 |
NOTE: Same rates for On-Peak and Off-Peak hours. Typical training time: 3 Hours. Training is billed per hour per person. Usage is billed per hour.
Keycard Access: | Daytime or 24/7 |
Instrument Access: | Daytime or 24/7 |
NOTE: Keycard access is required at all times to enter the TEM Labs. Users who have yet trained are not permitted to operate any lab instruments. Users who wish to bring guests are required to notify the Lab Manager in advance.

Description
Tosca 400 AFM is a compact system with a large sample stage that enables users to detect surface topography down to atomic steps. This AFM not only provides basic surface imaging in both contact tapping mode and contact mode but also several advanced modes such as Magnetic force microscopy (MFM), Kelvin Probe Force Microscopy (KPFM), Conductive Atomic Force Microscopy (C-AFM), Current Control Conductive Atomic Force Mode (CCC-AFM) and force-distance measurement.
More details can be found here.
This AFM is a loaner system offered by Anton Paar GmbH whose generous offer is highly appreciated.
Instrument Features
- Two Imaging Modes (Tapping and Contact)
- Four advanced modes (KPFM, C_AFM, CCCFM, and MFM)
- User-Friendly Operation Interfaces
- Large Sample Stage to Hold A 90 mm Wafer
- Specially-designed AFM Cantilever Exchange Tool to Make the Cantilever Exchange Easily and Accurately
Popular Applications
- Surface Topographic Imaging
- Kelvin Probe Force Microscopy (KPFM)
- Conductive Atomic Force Microscopy (C-AFM)
- Force-Distance Curve Measurement
- Magnetic force microscopy (MFM)
Instrument Specifications
X-Y scan range | up to 100 µm |
Z-range | up to 15 µm |
Max scan speed | 10 lines/s |
Max sample height | 25 mm |
Max sample weight | 600 g |
NOTE: More specifications and some applications are listed on the Anton Paar website.
Useful Information
Instruction & Brochure
Application Notes
SOP & Safety Documents
Standard Operating Procedures and other instrument-specific documents are available to users who have received in-person training.
Vendor Contact
Anton Paar USA Inc.
Regional Office – West
2824 Columbia Street
Torrance, CA 90503
Tel. +1 (310) 775-2196
Fax +1 (804) 550-1057
info.us@anton-paar.com