Waters Advanced Polymer Chromatography (APC) w/ Wyatt μDAWN Multi-Angle Light Scattering (MALS) and Optilab UT-rEX Refractive Index (RI) Detectors

Description

The Waters-Wyatt APC-MALS-RI system combines a very high definition Waters APC system enables fast fractionation of polymers with Wyatt MALS and RI detectors which provide fast and accurate measurements of the absolute molecular weight, particle size and distribution, and even 3D geometry features of synthetic or natural macromolecules across a broad range of molecular weights (3000 ~ 2,000,000 g/mol). The default solvent is THF and can accommodate DMF and other solvents upon request. Automatic sample management and injection allow for the analysis of large sample sets.

The APC-MALS-RI system consists of an ACQUITY APC system composed of an isocratic solvent manager (p-ISM), a sample manager with a flow-through needle (SM-pFTN), and a single zone column manager (CM-S) and two essential analysis instruments: Wyatt μDAWN multi-angle light scattering detector for absolute measurement of polymer radius of gyration and weight-averaged molecular weight and Wyatt OptiLab T-rEX for measurement of analyte concentration and determination of solution refractive index.

Instrument Features

Isocratic Solvent Manager of Up to 6 Solvents. Sample Manager for Automatic Measurements. Column Bank Housing Multiple Columns. Column Bank for Multiple Mobile Phases. eCord Intelligent Chip Technology. Ultrahigh Pressure Enabled. Multi-Angle Laser Scattering System. In-Series Refractive Index Detector.

Popular Applications

Molecular Weight Determination of Polymers. Polymer Fractionation. Particle Size and Shape Determination. Polymer Branching. Polydispersity of Polymers. Absolute and Increment of Refractive Index.

Instrument Specifications

Maximum Operating Pressure: 15,000 psi
Flow Rate Range: 0.010 to 2.000 mL/min (solvent dependent)
Flow Accuracy: ±1.0% at 0.5 to 2.0 mL/min
Flow Precision: ≤0.075% RSD or ≤0.020 min SD
Flow Drift: ≤0.2%
Operation Temperature: Ambient Temperature
Injection Volume Range: 0.1 to 50 μL
Injection Accuracy: ±0.2 μL
Recommended Sample Volume: 0.5 to 1 mL
Recommended Sample Concentration: 0.1 to 10 mg/mL (dependent on molecular weight)

Vendor Contact

Waters Corporation

34 Maple Street, Milford, MA 01757 U.S.A.
T: 1 508 478 2000 F: 1 508 872 1990
www.waters.com

Wyatt Technology Corporation

6300 Hollister Avenue, Santa Barbara, CA 93117
Tel: +1 (805) 681-9009 ▪ Fax: +1 (805) 681-0123
www.wyatt.com ▪ support@wyatt.com

SOP & Knowledgebase

TEMPR Lab maintains an ever-growing knowledge base relevant to all techniques involved in the lab. This information together with instrument SOPs is made available to all trained users through shared Google Drive.