TA Instruments Discovery Series DSC 2500 with RCS90 Cooler

Description

Discovery series DSC 2500 from TA Instruments offers streamlined material testing with high accuracy and sensitivity in determining materials phase transition parameters, e.g., melting, crystallization, or glass-transition temperatures, as well as corresponding enthalpies. These parameters are obtained through a precise DSC cell composed of a thermoelectric sensor surrounded by a furnace and a cooler, which enables precise control over heating and cooling rates within the operating range of the instrument (-90 to 400 °C under the current setting) while heat flow of the sample is measured against a reference.

An RCS90 cooler employs a two-stage refrigeration system to permit efficient cooling down to -90 °C.

The auto-sampler loads/unloads samples allowing for consecutive measurement of up to 54 samples, and a gas delivery module controls the purge gas to the furnace (gas 1 (N2); artificial air, He, Ar, O2 can be configured).

Available Purge Gases

Nitrogen, Helium, Argon, Oxygen

Available Sample Pans

Tzero® Aluminum & Tzero® Hermetic Aluminum

Instrument Features

Fusion Cell. MDSC. Standard Heat Flow. Tzero Heat Flow. Advanced Tzero Heat Flow (T4P). RCS90 Cooler. Direct Cp Measurement. User-Replaceable Cell. 54-Position Autosampler. Dual input Gas-Delivery Manifold. Color App-Style Touch Screen.

Popular Applications

Glass Transition of Polymers. Temperature/Enthalpy of Melting/Crystallization. Modulated DSC. Thermal Stability. Melting and Crystallization Kinetics. Materials Aging and Relaxation. Thermally Reversible and Irreversible Behavior. Polymorphic Transition.

Instrument Specifications

Baseline Flatness: (-50 to 300°C) ≤5 μW
Baseline Repeatability: (-50 to 300°C) <10 μW
Temperature Range: -90 °C to 400 °C
Temperature Accuracy: ±0.025 °C
Temperature Precision: ±0.005 °C
Enthalpy Precision: ±0.04%